Leads India

Single Beam UV Visible Spectrophotometer

Single Beam UV Visible Spectrophotometer

Wide spectral coverage and high resolution is achieved by using a powerful light source and a grating-based monochromator. A conveniently placed control enables the user to quickly orient the grating to provide monochromatic light of desired wavelength. The electronic processing circuits and power supplies are solid-state / LSI-based to ensure high accuracy, stability and long life.
104
Specification:
  • Wavelength
  • Range – 340 to 960 rim
  • Wavelength
  • Accuracy – ±5 nm
  • Wavelength
  • Readout – 5 nm
  • Wavelength Display – Dial
  • Spectral Bandwidth – 10 nm
  • Photometric Accuracy – +0,005 Abs at 1.000 Abs
  • Photometric Resolution – 0.1%T, 0.001 Abs
  • Photometric Readout – 4 digit Seven Segment LED
    Grating – 600 linesimm
  • Source – Tungsten halogen lamp
  • Detector – Wide Range Silicon Photodiode
  • Sample Holder – Single position 10 mm cuvette holder
  • Min. Sample Volume – 1 ml in 4 ml cuvette
  • Measuring Mode -Auto
    a)%Transmittance
    b) Absorbance
    c) Concentration 230V,
  • Power – +10%, 50Hz 420(W) X 310(D)
  • Dimension – X 125(H) mm
  • Weight – 6.5 Kg (Approx)
  • Accessories – Two Glass Cuvettes
  • Optional Accessories -Single Position 20150 mm Cuvette Holder (Factory Installed)
105
Specification:
  • Wavelength
  • Range – 340 to 960 rim
  • Wavelength
  • Accuracy – ±5 nm
  • Wavelength
  • Readout – 5 nm
  • Wavelength Display – Dial
  • Spectral Bandwidth – 10 nm
  • Photometric Accuracy – +0,005 Abs at 1.000 Abs
  • Photometric Resolution – 0.1%T, 0.001 Abs
  • Photometric Readout – 4 digit Seven Segment LED
    Grating – 600 linesimm
  • Source – Tungsten halogen lamp
  • Detector – Wide Range Silicon Photodiode
  • Sample Holder – Single position 10 mm cuvette holder
  • Min. Sample Volume – 1 ml in 4 ml cuvette
  • Measuring Mode -Manual
    a)%Transmittance
    b) Absorbance
    c) Concentration 230V,
  • Power – +10%, 50Hz 420(W) X 310(D)
  • Dimension – X 125(H) mm
  • Weight – 6.5 Kg (Approx)
  • Accessories – Two Glass Cuvettes
  • Optional Accessories -Single Position 20150 mm Cuvette Holder (Factory Installed)
106
Specification:
  • Wavelength – 340 to 960 nm
    Absorbance Range – -0.3 to 2.500 Abs
    Spectral Bandwidth – 5nm
    Wavelength Resolution – 5nm
    Wavelength Display – Dial
    Wavelength Accuracy – +5 nm
    Photometric Resolution – 0.1%T
    Photometric Accuracy – ±0.005 Abs at lAbs
    Modes – %T, Abs, Concentration & Factor
    Concentration – 0.000 to9999 with floating Decimal point
    K factor – 0.000 to9999 with floating Decimal point
    Photometric Readout – 4 Digit LED Display
    0 & 100%T Setting – Manual
    Grating – 600 linesirnm
    Detector – Si-Photo- Diode
    Source – Halogen Lamp
    Sample holder – l Omm path length,
    Two Position Manual Sample Changer
    Power – 230V ±-10%, 50Hz
    Dimension Weight – 420(W) X310 (D) X 125(H) mm 6.5 Kg (Approx)
    Accessories – Two Glass Cuvettes
166
Specification:
  • Wavelength – 340 to 960 nm
    Absorbance Range – -0.3 to 2.500 Abs
    Spectral Bandwidth – 5nm
    Wavelength Resolution – 5nm
    Wavelength Display – 3 Digital dial
    Wavelength Accuracy – +2 nm
    Photometric Resolution – 0.1%T
    Photometric Accuracy – ±0.005 Abs at lAbs
    Modes – %T, Abs, Concentration & Factor
    Concentration – 0.000 to9999 with floating Decimal point
    K factor – 0.000 to9999 with floating Decimal point
    Photometric Readout – 4 Digit LED Display
    0 & 100%T Setting – Manual
    Grating – 600 linesirnm
    Detector – Si-Photo- Diode
    Source – Halogen Lamp
    Sample holder – l Omm path length,
    Two Position Manual Sample Changer
    Power – 230V ±-10%, 50Hz
    Dimension Weight – 420(W) X310 (D) X 125(H) mm 6.5 Kg (Approx)
    Accessories – Two Glass Cuvettes
  •  
167
Specification:
  • WAVELENGTH
    Range-340 to 999 nm
    Accuracy-±2.0 nm
    Readout-1 nm step
    Bandwidth-5.0 nm
    PHOTOMETRIC
    Range–0.04 to 2.5 Abs
    Accuracy-10.005 Abs at 1.0 Abs
    Repeatability -±0.005 Abs
    Resolution-0.1 in %T mode, 0.001 Abs in Abs mode
    Digital Readout-2 line 20 characters LCD
    Drift- ±0.003 Abs/hour at 500 nm ±0.005 Abs
    Baseline Flatness Stray Light -Less than 0.3%T at 370 rim
    GRATING – 600 lines/mm
    SOURCE – Tungsten-Halogen lamp
    DETECTOR – Silicon Photodiode
    SAMPLE HOLDER-Two-position manual sample changer or factory installed single position holder for
    20 mm / 50 mm (Max) path length cell.
    MINIMUM. VOLUME
    0,100%T, ORDER-1 ml in 4 ml cuvette
    CUTOFF SETTING – automatic
    OPERATING MODES Automatic
    i) Single Wavelength
    ii) Multi Wavelength (max 6)
    iii) Scan
    MEASURING MODES-i) Absorbance
    ii) %Transmittance
    iii) Concentration (with factor and curve fitting)
    K-Factor Range Concentration Range – 0.100 to 9999 with floating Decimal point
    0.100 to 9999 with floating Decimal point
    DATA PROCESSING- 1) Peak Pick (6 peaks in Abs value)
    2) Spectrum printout
    (on Epson compatible Dot Matrix printer)
    DATA PRESENTATION
    Display-2 line 20 char. Alphanumeric LCD
    Hard Copy-On printer (Graph and Data both)
    PRINTER PORT-Epson compatible 80 Column Dot Matrix
    RS 232 PORT -PC Link data transfer
    POWER-230V 110%, 50 Hz
    DIMENSIONS-420 (W) X 310 (ID) X 125 (H) mm
    WEIGHT-6.5 kg (Approx)
    ACCESSORIES-2 matched 10 mm path length Glass cuvettes
169
Specification:
  • Wavelength – 320-990nm
    Absorbance Range – -0.3 to 2.500 Abs.
    Spectral Bandwidth – 5nm
    Wavelength Resolution – 1nm
    Wavelength Display – Digital
    Wavelength Accuracy – ±2nm
    Photometric Resolution – 0 . 1`)/0 T
    Photometric Accuracy at 1 Abs. – ±0.005 Abs.
    Modes – %T, Abs., Concentration & Factor
    Concentration – 0.000 to 9999 with floating Decimal point
    K factor – 0.000 to 9999 with floating Decimal point
    Photometric Readout – 4 Digit LED Display
    0& OCr/oT Setting – Auto
    Grating – 600 lines/mm
    Detector – Si-Photo- Diode
    Source – Halogen Lamp 12V-50W
    Sample holder – lOmm path length, Two Position Manual Sample Changer
    Power (SMPS) – 230V±10°/050Hz
    Printer – Printer Port for 80 Column DMP
    Optional – 20mm/50mm Single Position Factory Installed Holder For Computer attachment RS232 interface port
1203
Specification:
  • WAVELENGTH
    Range – 340 to 999 nm
    Accuracy – ±2 nm
    Readout – 1 nm per step
    Bandwidth-5 nm
    PHOTOMETRIC
    Range-±2.5 Abs
    Accuracy-±0.005 Abs at 1.0 Abs
    (with NIST filter)
    Repeatability Resolution- ±0.005 Abs
    Display-0.1%T, 0.001Abs
    Drift-4 Line 20 Ch. LCD
    Baseline Flatness : ±0.003 Abs / hour at 500 nm
    Scan Speed – ±0.005 Abs
    Grating
    Source – Slow, Medium & Fast
    Detector – 600 lines/mm
    Sample Holder : Tungsten halogen lamp 2-Silicon Photodiode
    Minimum Volume : One (10 mm) fixed for Reference & Sample cuvette holder
    Operating Mode :1 ml in 4 ml cuvette with cell riser Single wavelength, Multi wavelength (Max 8), Spectrum scan and Time scan
    Measuring Mode :
    K-Factor Range Conc .Range– Absorbance, “%Transmittance and Concentration (with by factor and by standard curve fitting)
    Data Processing :0.100 to 9999 with floating
    decimal point
    0.100 to 9999 with floating
    decimal point
    Stray Light-Peak pick/Valley picks (6 points) Point picks
    Printer Port -(8 point), First derivative, Data saving facility (Four user defined files for each mode) Test saving facility (Four user defined files for each mode)
    RS232 Port Power -< 0.3%T at 370 nm
    Dimension Weight defined files for each mode)
    Accessories Optional -Epson compatible 80 column Dot Matrix
    Accessories– PC Link data transfer
    230 V ±10 % , 50 Hz
    450(W) X 360(D) X 130(H) mm
    9 Kg (Approx)
    Two 10 mm glass cuvette
    n PC link software
    • Epson compatible D. M. Printer
    • Multi cuvette holders for 20/40/50 mm rectangular cuvette
    (Factory Installed)
117
Specification:
  • OPTICS : Modified Czerny – Turner Monachromator geomety for better aberration correction with Holographic Grating of 1200 lines/mm blazed at 250 nm.
  • WAVELENGTH
    Range : 200 to 1100 nm
    Resolution : 0.1 nm
    Accuracy : 1 nm
    Repeatability : t 0.5 nm
    Bandwidth : 2 nm
  • PHOTOMETRIC
    Range : 0 to 2.5Abs
    Accuracy : 0.005 Abs at IA
    Repeatability : 0.002A bs at I A
    Drift : 0.003 Abs /hr (After 1 hr warmup at 500 nm)
  • STRAY LIGHT
    Less then O. 1% T at 220 nm 8: 370 nm
  • BASELINE CORRECTION Automatic baseline correction
  • BASELINE FLATNESS
    0.003 Abs /hr (After 40 minutes warm-ups)
  • MEASURING MODES
    %Transmittance
    Absorbance
    Concentration by K-factor and Multi-standards
  • OPERATING MODES
    Single Wavelength
    Multi Wavelength
    Spectrum Scan
    Time Scan
  • DATA PROCESSING : Stand Alone • Peak-Pick • Spectrum printout
  • SCAN SPEED : Low, Medium and High
  • DATA INTERVAL : Depends on wavelength scan-span & Scan-speed
  • SAMPLE HOLDER : 5 position for 10 mm cuvette (automatically) SAMPLE VOLUME 2 ml in 4 ml cuvette or 500 pi in 1 ml cuvette SOURCE : Tungsten Halogen Lamp (320 to 1100 nm)
    Deuterium Lamp (200 to 340 nm)
  • DETECTOR : UV – enhanced wide range solid state photodiode DISPLAY : 20 character, 41ine backlit alphanumeric LCD KEYBOARD :18 keys (11 numeric and 7 functional)
  • PRINTER PORT : Epson compatible 80 Column Dot Matrix RS 232 PORT : PC Link data transfer
  • POWER 230V ±10%, 50 Hz
  • DIMENSIONS : 560 (W) X 425 (D) X 205 (H) mm
  • WEIGHT :21 kg (Approx)
  • ACCESSORIES : Two matched 10 mm path length Quartz cuvettes
  • OPTIONAL ACCESSORIES
    Holder for 50 mm or 100 mm cylindrical and rectangular cuvettes
    Personal Computer / Laptop
    Epson compatible 80 column D.M. Printer
    Standard RS 232 interface for Window based PC link Software for Spectrum Display, Storage/Retrieve, Peak-Pick, Point – Pick, Expansion of spectra, I 3r’l& 4’1′ Derivatives, Averaging of Scans,
    Subtraction of Two Scans