Reactor Autoclave
Reactor Autoclave
A reactor autoclave is a high-pressure, high-temperature vessel designed to carry out
chemical reactions, sterilization, and media preparation in a controlled and safe environment.
Unlike regular autoclaves, reactor autoclaves allow precise control over temperature,
pressure, and mixing, making them essential in pharmaceutical, chemical, biotechnology, and
research laboratories. We are the best reactor autoclave manufacturers in Chennai.
Modern Lab Intelligent Automation
Systems with microprocessors reduce the need for manual intervention. Chemical reaction
and sterilization cycles are pre-programmed. Instant alerts and notices make monitoring
smooth. The elimination of inaccurate temperature and pressure, along with having the same
level of heating and cooling throughout the chamber, ensures consistent results. Variable
pressure allows the system to meet various chemical procedures, and safety interlocks
provide protection to the user and avoid the possibilities of errors during operation.
Customizable and Modular Reactor Design
Reconfigurable reactor vessels of different sizes and capacities. Adjustable stirring and
mixing capabilities allow complicated reactions. The system is scalable to pharmaceutical,
chemical, and research laboratory requirements.
Environmentally Friendly and Energy-Effective Performance
Lossless insulation decreases power humiliation. Quick cooling and heating processes
conserve time and energy. Sustainable lab setups use environmentally friendly materials.
Smart Safety Integration
Emergency auto pressure release valves. Leaks are avoided by durable seals and reinforced
chambers. Constant electronic surveillance guarantees the absolute safety of the operators.
Monitoring Improved Workflows
Loading and cleaning the vessels is easy and fast. The small size will fit on a benchtop or on
the floor. Reduced cycle time enhances productivity and efficiency of the lab.
Industrial Applications
● Pharmaceutical Labs: The synthesis of drugs, their sterilization, and media.
● Chemical Research Laboratories: Barocentric reactions and controlled reactions.
● Biotechnology Facilities: Culture media preparation and safe chemical reactions.
● Materials Science Laboratories: Polymerization, nanoparticle synthesis, and composites studies.
Why Choose Leads India?
High-quality, externalized reactor autoclaves. Standardized solutions to fit laboratory or
industrial needs. Good after-sales services and quick services on maintenance services. Leads
India provides reactor autoclaves with a combination of accuracy, safety, and efficiency,
enabling laboratories and industries in Chennai to attain a high level of precision in the
results and maintain high standards of safety and productivity. We are the best reactor
autoclave manufacturers in Chennai.
Reactor Autoclave
Cat No LI-100 ml
Specification
- Maximum Operating Capacity 50 ml
- Minimum Operating Capacity 25 ml
- L/D Ratio 1.4
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.
Reactor Autoclave
Cat No LI-400 ml
Specification
- Maximum Operating Capacity 200 ml
- Minimum Operating Capacity 80 ml
- L/D Ratio 1
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.
Reactor Autoclave
Cat No LI-750 ml
Specification
- Maximum Operating Capacity 400 ml
- Minimum Operating Capacity 80 ml
- L/D Ratio 1.39
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.
Reactor Autoclave
Cat No LI-1000 ml
Specification
- Maximum Operating Capacity 600 ml
- Minimum Operating Capacity 80 ml
- L/D Ratio 1.94
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.
Reactor Autoclave
Cat No LI-2000 ml
Specification
- Maximum Operating Capacity 1200 ml
- Minimum Operating Capacity 150 ml
- L/D Ratio 1.96
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.
Reactor Autoclave
Cat No LI-3500 ml
Specification
- Maximum Operating Capacity 3500 ml
- Minimum Operating Capacity 500 ml
- L/D Ratio 1.54
- Motor Rating 0.25 HP
- Standard Design Pressure 00 Kg/cm2 g
- Standard Design Temperature 250°C
- Optional Design Pressure Available upto 350 Kg/cm2 g
- Optional Design Temperature Available upto 600°C
- Automation Grade Fully Automatic
- Usage/Application Research
- Mount Type Floor Mounted Autoclave
- Temperature Range 121 – 600 Degree Celsius
- Material SS316,SS316 L,Hastelloy C,Zirconium,Inconel,Monel
- Insulation Wall Double Wall
- Accessories Flameproof Control Panel,Auto Cooling System,Digital Pressure Indicator,Safety Relief Valve,Flam
- Advantages:
- High Mass transfer area
- Faster reaction
- Shorter batch time
- Lesser catalyst loading
- Minimum Impurities
- High Yields
- Better Product Economy
- Applications:
- For various high pressure reactions and gas-liquid reactions with Hydrogen
- Ethlyene Oxide
- Ammonia
- Oxygen
- HCL
- Phosgene
- CO2
- CO
- In R & D Labs of fine & specialty chemicals, bulk drug manufacturers, agrochemicals, petrochemicals companies and chemical / chemistry departments of educational institutes / Universities etc.