Class III Biological Safety Cabinet
Class III Biological Safety Cabinet
Fully Sealed Isolation
● Only glove ports are used in working.
● Nonexistent exposure to samples or aerosols.
● Is totally insulated against the operator and the environment.
High-Security Air System & Triple Filtration
● These cabinets have a 100% exhaust HEPA/ULPA filtration system that avoids the release of toxic and infectious agents to the facility.
● The leakage is removed by negative pressure.
● Redundant safety filters allow the necessary control of contamination.
Built for Extreme Bio-Research Missions
Purpose-designed for:
● Infectious disease and virology.
● Vaccine manufacturing & live viruses.
● Bio defense labs established by governments.
● Dealing with genetically altered or unfamiliar pathogens.
The working chamber has a stable sterile environment even when the high-risk operations are continuous.
Technology that Assists the Researcher
● Quick reaction alarms and pressure gauges.
● Smooth welded walls to facilitate sterilization.
● Fumigating surfaces made of chemicals.
Class III Biological Safety Cabinet - GI Powder coated
Cat No LI- SPB-BS-C3-900-GI
Specification
- MOC G I With Powder Coated
- Dimension 3 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt
Class III Biological Safety Cabinet - GI Powder coated
Cat No LI- SPB-BS-C3-1200-GI
Specification
- MOC G I With Powder Coated
- Dimension 4 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt
Class III Biological Safety Cabinet - GI Powder coated
Cat No LI- SPB-BS-C3-1800-GI
Specification
- MOC G I With Powder Coated
- Dimension 6 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt
Class III Biological Safety Cabinet - Stainless Steel
Cat No LI- SPB-BS-C3-900-SS
Specification
- MOC G I With Powder Coated
- Dimension 3 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt
Class III Biological Safety Cabinet - Stainless Steel
Cat No LI- SPB-BS-C3-1200-SS
Specification
- MOC G I With Powder Coated
- Dimension 4 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt
Class III Biological Safety Cabinet - Stainless Steel
Cat No LI- SPB-BS-C3-1800-SS
Specification
- MOC G I With Powder Coated
- Dimension 6 X 2 X 2
- Air balancing 0%recirculation & 100% exhaust with double HEPA filtration
- Cleanliness Class 100 /ISO Class 5 as per ISO 14644-1
- Front door By 5mm clear Toughen glass –sliding Door
- Air Volume at Initial Velocity Cabinet Negative
- Pressure Minimum 0.5” Negative pressure as per NSF 49
- Front door By 5mm clear Polycarbonate Door –Air Tight Construction with Pneumatic Lift. Single side Pass box designed to avoid cross contamination entry
- AIR FLOW: Designed fore 0.4m/s to 0.65 m/s when measure across the entire filters Space during the rated life cycle of filters.
- PRE- FILTER: Media : Synthetic, Non-oven Polyester fiber, Washable Type.
- Gasket : Neoprene Retention 5 Micron
- Efficiency : 95%
- Pressure Drop: 6 to 8 mm
- HEPAFILTER
- Media : Ultra clean glass fiber paper-imported
- Gasket : Neoprene
- Retention : 0.3Micron
- Efficiency : 99.97%
- Pressure Drop: 25 mm of W.c.
- Noise Level Below 65dB on “A” scale
- ILLUMINATION 4 feet, 40 watts florescent tube lights
- >800 Lux at measured at work surface level
- Ultra violet lamp 3 feet, 30 watts
- Work Surface
- IS 304 grade Stainless steel with Satin finish
- Differential Pressure (^P) – 1 No
- 0-25mm Magnehelic Gauge for HEPA filter
- Negative Pressure 12mm
- Motor Blower (supply air) 1440 rpm single phase
- Power Sockets 15 amp 2 No’s inbuilt