Formaldehyde Sterilizer
Formaldehyde Sterilizer
- Cat No: L1235
Exceptional Precision Sterilization Technology
Our formaldehyde sterilizers are used to provide full sterilization by exposing to uniform heat and gas. Every cycle will be programmed to ensure that sterilization is always constant to Protect sensitive equipment and materials against contamination.
Features:
● Regulated Dispersion of Gases: Formaldehyde vapor is dispersed evenly so that maximal sterilization can be achieved.
● Microprocessor-Driven Systems: Automatically control temperature, pressure, and sterilization.
● Energy-Saving Performance: Heating and ventilation are optimized to save energy.
● Automatic Safety Mechanisms: There are safety interlocks and emergency pressure release valves that avoid accidents.
The design is easy to use and reliable.
Our sterilizers are created with smooth operation in routine laboratory and industrial processes.
● Intuitive Display Panel: The display has a clear indication of pressure, temperature, and the status of the cycle.
● Small and Miniature construction: Easily fits on laboratory benchtops or industrial floors.
● Fast Sterilization Windows: Time savings, and they do not affect the quality of sterilization.
Applications in Industries
● Pharmaceutical Laboratories: Instrument and packaging material sterilization.
● Biotechnology Plants: Culture media and sterilization of laboratory instruments.
● Medical Device Manufacturers: Guarantees sterility of equipment.
● Research/Educational Labs: Experiment/Demonstration safe sterilization.
Why Choose Leads India?
Formaldehyde Sterilizer Machine
Cat No LI- BI-FS-S
Specification
- Chamber Capacity : 600ltrs
- Door : Vertical Sliding / Radial Locking Double Door with Pneumatic Operation
- Door Safeties : Cycle will not start until the door is shut properly, Door automatically stops if an obstruction is detected, Door cannot be opened when the chamber is pressurized, Prevents both doors from being opened simultaneously.
- Inner Chamber, Door, Steam Generator and Jacket : SS 316 L
- Insulation for Jacket and Doors : 60 mm Chloride free mineral wool.
- Pipes and Valves: Piping system made up of SS304 with Pneumatic Operated Piston type valve
- Steam Generator : Inbuilt Steam Generator made up of SS 316L, 50 mm Chloride free mineral wool, Safety Valve, Heating capacity of 45Kw.
- Vacuum Pump: High capacity efficient liquid ring type vacuum pump with Condenser for pre and Post Vacuum Pulsing
- Automatic Water Pump : High Pressure Feed water Pump for Automatic Water Filling.
- Operating Interface : Dual PLC control Based Fully Automatic HMI 7” Touchscreen on Both Loading and Unloading Side with COM ports for printer & PC communications, Password Protected, Data Logging facility, Different setting of cycles which are pre selectable and Editable as per User requirement, HMI displays Chamber Temperature, Pressure, Time, Date, Cycle No, Batch No, alert message with Audio visual alarm for Chamber and Steam Generator High Pressure and Temperature, Low Water level in Generator, Vacuum pump and Water pump error, Temperature and Pressure sensor failure.
- Automatic Program Cycles : 65oC Formalin Process, 80oC Formalin Process, 121oC Steam Sterilization Process, 134oC Steam Sterilization Process, Bowie-Dick Test, Leak Rate Test, Rapid Cooling process.
- Sensors : Two Temperature probes and Two Pressure Transducers for chamber and Jacket with temperature accuracy of ±0.1°C and pressure accuracy of 1%
- Formalin Injection : Through sealed bottle can be used for 2 cycles
- Printer: Alpha numeric Printer which prints whole cycle parameters
- Air Filter : HEPA air filter with 99.99% of efficiency for particle less than 0.3µm.
- Data logging : Viewed through HMI and also can be stored in the system through SD card.
- Jacket cooling system for sudden loading of LTSF from high Temperature Cycle.
- HCHO Monitoring the level and consumed quantity displayed at the End Cycle.
Formaldehyde Sterilizer Machine
Cat No LI- BI-FS-225
Specification
- Chamber Capacity : 225ltrs
- Door : Vertical Sliding / Radial Locking Double Door with Pneumatic Operation
- Door Safeties : Cycle will not start until the door is shut properly, Door automatically stops if an obstruction is detected, Door cannot be opened when the chamber is pressurized, Prevents both doors from being opened simultaneously.
- Inner Chamber, Door, Steam Generator and Jacket : SS 316 L
- Insulation for Jacket and Doors : 60 mm Chloride free mineral wool.
- Pipes and Valves: Piping system made up of SS304 with Pneumatic Operated Piston type valve
- Steam Generator : Inbuilt Steam Generator made up of SS 316L, 50 mm Chloride free mineral wool, Safety Valve, Heating capacity of 45Kw.
- Vacuum Pump: High capacity efficient liquid ring type vacuum pump with Condenser for pre and Post Vacuum Pulsing
- Automatic Water Pump : High Pressure Feed water Pump for Automatic Water Filling.
- Operating Interface : Dual PLC control Based Fully Automatic HMI 7” Touchscreen on Both Loading and Unloading Side with COM ports for printer & PC communications, Password Protected, Data Logging facility, Different setting of cycles which are pre selectable and Editable as per User requirement, HMI displays Chamber Temperature, Pressure, Time, Date, Cycle No, Batch No, alert message with Audio visual alarm for Chamber and Steam Generator High Pressure and Temperature, Low Water level in Generator, Vacuum pump and Water pump error, Temperature and Pressure sensor failure.
- Automatic Program Cycles : 65oC Formalin Process, 80oC Formalin Process, 121oC Steam Sterilization Process, 134oC Steam Sterilization Process, Bowie-Dick Test, Leak Rate Test, Rapid Cooling process.
- Sensors : Two Temperature probes and Two Pressure Transducers for chamber and Jacket with temperature accuracy of ±0.1°C and pressure accuracy of 1%
- Formalin Injection : Through sealed bottle can be used for 2 cycles
- Printer: Alpha numeric Printer which prints whole cycle parameters
- Air Filter : HEPA air filter with 99.99% of efficiency for particle less than 0.3µm.
- Data logging : Viewed through HMI and also can be stored in the system through SD card.
- Jacket cooling system for sudden loading of LTSF from high Temperature Cycle.
- HCHO Monitoring the level and consumed quantity displayed at the End Cycle.
Formaldehyde Sterilizer Machine
Cat No LI- BI-FS-1000
Specification
- Chamber Capacity : 1000 ltrs
- Door : Vertical Sliding / Radial Locking Double Door with Pneumatic Operation
- Door Safeties : Cycle will not start until the door is shut properly, Door automatically stops if an obstruction is detected, Door cannot be opened when the chamber is pressurized, Prevents both doors from being opened simultaneously.
- Inner Chamber, Door, Steam Generator and Jacket : SS 316 L
- Insulation for Jacket and Doors : 60 mm Chloride free mineral wool.
- Pipes and Valves: Piping system made up of SS304 with Pneumatic Operated Piston type valve
- Steam Generator : Inbuilt Steam Generator made up of SS 316L, 50 mm Chloride free mineral wool, Safety Valve, Heating capacity of 45Kw.
- Vacuum Pump: High capacity efficient liquid ring type vacuum pump with Condenser for pre and Post Vacuum Pulsing
- Automatic Water Pump : High Pressure Feed water Pump for Automatic Water Filling.
- Operating Interface : Dual PLC control Based Fully Automatic HMI 7” Touchscreen on Both Loading and Unloading Side with COM ports for printer & PC communications, Password Protected, Data Logging facility, Different setting of cycles which are pre selectable and Editable as per User requirement, HMI displays Chamber Temperature, Pressure, Time, Date, Cycle No, Batch No, alert message with Audio visual alarm for Chamber and Steam Generator High Pressure and Temperature, Low Water level in Generator, Vacuum pump and Water pump error, Temperature and Pressure sensor failure.
- Automatic Program Cycles : 65oC Formalin Process, 80oC Formalin Process, 121oC Steam Sterilization Process, 134oC Steam Sterilization Process, Bowie-Dick Test, Leak Rate Test, Rapid Cooling process.
- Sensors : Two Temperature probes and Two Pressure Transducers for chamber and Jacket with temperature accuracy of ±0.1°C and pressure accuracy of 1%
- Formalin Injection : Through sealed bottle can be used for 2 cycles
- Printer: Alpha numeric Printer which prints whole cycle parameters
- Air Filter : HEPA air filter with 99.99% of efficiency for particle less than 0.3µm.
- Data logging : Viewed through HMI and also can be stored in the system through SD card.
- Jacket cooling system for sudden loading of LTSF from high Temperature Cycle.
- HCHO Monitoring the level and consumed quantity displayed at the End Cycle.