Fully Automatic Hospital Autoclave
Fully Automatic Hospital Autoclave
Next-Generation Sterilization Control
● Operated with smart systems based on microprocessors that make all the sterilization
cycles uniform and mistake-free.
● Fully automated temperature, pressure, and time control, which means low levels of manual control but full control of the equipment with full accuracy.
Strength and Design of Hospitals of Grade
● Long-life stainless-steel body can be used under high-pressure conditionscontinuously.
● High-capacity chambers enable sterilization of high loads of instruments, leading to less downtime and higher productivity.
Smart Safety Engineering
● Long-life stainless-steel body can be used under high-pressure conditionscontinuously.
● High-capacity chambers enable sterilization of high loads of instruments, leading to less downtime and higher productivity.
Easy Use with Computerized Accuracy
● Modern digital interface for selecting preset cycles, tracking process, and maintenance alerts.
● User-friendly structure saves on training and makes use trouble-free.
Predictable Personality in Applications
● Hospitals & Surgical Centers: To sterilize surgical kits, gowns, and linens.
● Medical Colleges: Funds for teaching and research laboratories, sterilization.
● Diagnostic Laboratories: Certifies that the instruments and media are
contamination-free.
Why Leads India?
Specification
- CHAMBER Dia 400 X 600 mm
- Volume 75 ltrs
- Power 6 kw
- Dimension 650x850x1600 mm
- Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 400 X 1100 mm
- Volume 138 ltrs
- Power 9 kw
- Dimension 650x1350x1600 mm Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 500 X 900 mm
- Volume 176 ltrs
- Power 9 kw
- Dimension 950x1500x190 mm
- Door Lock Radial
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 500 X 1100 mm
- Volume 216 ltrs
- Power 9 kw
- Dimension 950x1700x1900 mm
- Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 500 x 1200 mm
- Volume 235 ltrs
- Power 9 kw
- Dimension 950 x1800x1900 mm
- Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 600 X 900 mm
- Volume 254 ltrs
- Power 12 kw
- Dimension 1050x1500x1900 mm
- Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged
Specification
- CHAMBER Dia 750 X 1200 mm
- Volume 520 ltrs
- Power 18 kw
- Dimension 1200x1800x1900 mm
- Door Lock Single Point
- Door: Single door with Radial locking system
- Mode of control: With a multiport valve / Automatic Optional
- Door: SS Door Wing Nut/ Radial Locking
- Pre-vacuum and post vacuum: To eliminate air packs and ensure effective sterilization.
- Water protection: In the event of low water the supply to the heaters is discontinued automatically and visually indicated in the control panel.
- Pressure switch: An automatic pressure switch adjustable type is provided to set the required pressure.
- Vacuum drying: An effective vacuum drying is caused with powerful ejector and vacuum breaker which draws air from the atmosphere. It is filtered, pre-heated(sterilized) and finally enters the working chamber for effective drying.
- Water Gauge glass: To note down the level of water glass tube with gauge is provided.
- Gasket: Silicon Expansion type
- Instrumentation:
- Safety Valve
- Vacuum Breaker
- Non-Return Valve
- Steam Trap
- Water Inlet And Water Outlet Valves
- The sequence of Automatic operation includes the following:
- Automatic water filling for the steam generator
- Leak test for required time and results with alarm will be displayed and data logged.
- Bowie-did test
- Spore-test results from approved lab submitted
- Pulsing ( vacuuming, purging and pre-heating)_ Optional
- Sterilization with temp and balance time displayed and data logged
- Exhaustion appropriate to liquid, instruments and fabric cycles.
- Drying cycle with the vacuum pump. – Optional
- Final cooling with admission of filtered air (0.2 Micron)
- Sterilization completes with F.O values Displayed and data’s logged